Inquiry

WLT60

GREEN SERIES
WLT60

The EOS Power Economical Green Series was designed with the value focused customer in mind. The WLT Green Series offers market leading specifications in industry standard footprints at very competitive price levels.

FEATURES
  • 50-65 W convection cooled rating.
  • Small 4.0 x 2.0 x 1.2 inches form factor.
  • High efficiency > 85%.
  • Single to triple outputs.
  • EN55022-B, FCC Part15 Level B.
  • No Load Power< 0.3 W
  • Class I & Class II options.
  • Cover Kit accessory available.
  • Now IEC/EN/UL62368-1 CompliantNEW
  • Approved with metal enclosures/accessories
AVAILABLE WITH COVER KIT
WLT60_Coverkit

WLT60-CK Series


Input Specifications
Input Voltage 90-264 V, Universal                                                                                                 
Input Frequency 4 47-400 Hz
Input Current 1.5 A max @ 120 VAC AND 0.75 A max @ 230 VAC
No Load Power < 0.3W for single output models
< 0.5W for multi output models
Inrush Current 30 A max @ 120 VAC AND 60 A max @ 230 VAC
Output Specifications
Output Voltage Refer model number matrix table.
Output Power 50 to 65 W
Hold-up Time >10 ms @ 120 VAC typical
Line Regulation +/-0.3 %
Load Regulation V1: +/-0.5 %; V2 & V3: +/-5 %
Minimum Load Refer model number matrix table.
Transient Response max excursion 10 %; 50-100 % step load change at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms.
Ripple1 Refer model number matrix table.
Rise Time < 100 ms
Set Point Tolerance V1: +/-3 %; V2 & V3: +/-5 %
Output Voltage Adjustment V1:+/- 10 %
Over Current Protection 130 % typical above rating
Over Voltage Protection 130 % typical for V1 only
Short Circuit Protection Short term, auto recovery
Cooling Convection
General Specifications
Efficiency5 120 VAC: 85 % typical AND 230 VAC: 85 % typical                                                                       
Isolation Voltage Input to Output 4000 VAC/VDC
MTBF 1.87m Hours, Telcordia -SR332-issue 3
Switching Frequency Approximately 67 kHz
Leakage Current 120 VAC: < 500 μA AND 230 VAC: < 1000 μA
Dimensions 4.0 x 2.0 x 1.2 inches
(101.6 x 50.8 x 30.48 mm)
Weight 150 gm approx
Environmental Specifications
Operating Temperature -20 to 70°C, refer derating curve,-20 to 0°C,startup is guaranteed                                                                 
Storage Temperature -40 to +85°C
Relative Humidity 95 % Rh, non condensing
Altitude Operating: 10,000 ft.; Non-operating: 40,000 ft
Model Number Power Supply Unit &
Its Installation Type
Maximum Wattage Voltage Max.Load3 Min. Load6 Ripples4
LFWLT60-1000-CKIn CK cover Kit635WV1=5.0 V7.0 A0.00 A1.5%
LFWLT60-1000In Open Frame

50W


V1=5.0 V


10.0 A


0.00 A


1.5%
LFWLT60-1000-LWith L Bracket
LFWLT60-1000-BWith Base Plate
LFWLT60-1000-UWith U channel
LFWLT60-1001-CKIn CK cover Kit645.5WV1=12 V3.79 A0.00 A1%
LFWLT60-1001In Open Frame

65W


V1=12 V


5.42 A


0.00 A


1%
LFWLT60-1001-LWith L Bracket
LFWLT60-1001-BWith Base Plate
LFWLT60-1001-UWith U channel
LFWLT60-1002-CKIn CK cover Kit645.5WV1=15 V3.03 A0.00 A1%
LFWLT60-1002In Open Frame

65W


V1=15 V


4.33s A


0.00 A


1%
LFWLT60-1002-LWith L Bracket
LFWLT60-1002-BWith Base Plate
LFWLT60-1002-UWith U channel
LFWLT60-1003-CKIn CK cover Kit645.5WV1=24 V1.89 A0.00 A1%
LFWLT60-1003In Open Frame

65W


V1=24 V


2.71 A


0.00 A


1%
LFWLT60-1003-LWith L Bracket
LFWLT60-1003-BWith Base Plate
LFWLT60-1003-UWith U channel
LFWLT60-1004-CKIn CK cover Kit645.5WV1=48 V0.94 A0.00 A1%
LFWLT60-1004In Open Frame

65W


V1=48 V


1.35 A


0.00 A


1%
LFWLT60-1004-LWith L Bracket
LFWLT60-1004-BWith Base Plate
LFWLT60-1004-UWith U channel
LFWLT60-3000-CKIn CK cover Kit642W
LFWLT60-3000In Open Frame


60W


V1=5.2 V
V2=12.5 V
V3=-12.8 V


V1=8.0 A
V2=3.0 A
V3=0.5 A


V1=0.5 A
V2=0.1 A
V3=0.0 A



V1=1.5 %,
V2 & V3=1 %
LFWLT60-3000-LWith L Bracket
LFWLT60-3000-BWith Base Plate
LFWLT60-3000-UWith U channel
LFWLT60-3001-CKIn CK cover Kit642W
LFWLT60-3001In Open Frame


60W


V1=5.2 V
V2=24 V
V3=-12.8 V


V1=8.0 A
V2=1.5 A
V3=0.5 A


V1=0.5 A
V2=0.1 A
V3=0.0 A



V1=1.5 %,
V2 & V3=1 %
LFWLT60-3001-LWith L Bracket
LFWLT60-3001-BWith Base Plate
LFWLT60-3001-UWith U channel
LFWLT60-3002-CKIn CK cover Kit642W
LFWLT60-3002In Open Frame


60W


V1=5.2 V
V2=15 V
V3=-15 V


V1=8.0 A
V2=2.5 A
V3=0.5 A


V1=0.5 A
V2=0.1 A
V3=0.0 A



V1=1.5 %,
V2 & V3=1 %
LFWLT60-3002-LWith L Bracket
LFWLT60-3002-BWith Base Plate
LFWLT60-3002-UWith U channel
LFWLT60-3003-CKIn CK cover Kit631.5W
LFWLT60-3003In Open Frame


45W


V1=3.3 V
V2=5 V
V3=-12.8 V


V1=6.0 A
V2=3.0 A
V3=0.5 A


V1=1.0 A
V2=0.1 A
V3=0.0 A



V1=1.5 %,
V2 & V3=1 %
LFWLT60-3003-LWith L Bracket
LFWLT60-3003-BWith Base Plate
LFWLT60-3003-UWith U channel
LFWLT60-CK metal cover kit accessory
General Notes:
  • Single output models deliver 65 W, except WLT60-1000 (50 W). Triple output models deliver 60 W, except WLT60-3003 (45 W).
  • Specifications are for nominal input voltage, 25°C and max. load unless otherwise stated.
  • Derate output power linearly to 80 % from 90 VAC to 80 VAC input.
  • When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
  • Please refer mechnical outline drawing for height of component above and below PCB for - 1xxx and 3xxx.
  • Class II version available. Add "-2" suffix at the end of the Model Number to Order. Enquire with EOS Sales Rep before Order.
Notes:
  1. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
  2. Min Load specified to meet cross regulation.
  3. Maximum current per output channel. Do not exceed total output power rating.
  4. Safety approved 47-63 Hz.
  5. For WLT60-3003 efficiency is 75 % typical.
  6. When used in Cover Kit, de-rate output power to 70 % under all operating conditions
Derating Curve
WLT60-1
De-rate linearly from 100% at 50°C to 50% at 70°C
WLT60-2
De-rate linearly from 70% at 50°C to 35% at 70°C
EMC
Parameter Conditions/Description Criteria
Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass
Radiated Emissions EN 55032 B Pass
Input Current Harmonics EN 61000-3-2 Class A
Voltage Fluctuation and Flicker EN 61000-3-3 Pass
ESD Immunity EN 61000-4-2 Level 3, Criterion A
Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A
Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A
Surge Immunity EN 61000-4-5 Level 3, Criterion A
Conducted Immunity EN 61000-4-6 Level 3, Criterion A
Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A
Voltage dips, interruptions EN 61000-4-11 Criterion A & B
Safety
CE Mark Complies with LVD Directive
Safety Standard(s) IEC60950-1(ed.2), EN 60950-1, UL60950-1 (2nd Edition), CSA C22.2 No. 60950-1 (2nd Edition),
UL 62368-1, 2nd Ed, 2014-12-01 CAN/CSA C22.2 No. 62368-1-14, 2nd Ed, Class1 SELV
IEC 62368-1:2014, EN 62368-1:2014; A11
Approval Agency Nemko, UL, C-UL
Safety File Number(s) Class I : Nemko: P15220205, NO88354 UL/C-UL: E150565, 20190628-E150565
Nemko Certificate No: P19223597 CB Test Certificate No: NO106819
Class II : Nemko: P13216532, NO72728 UL/C-UL: E150565
Downloads
CB Class - I Certificate
CB Class - II Certificate
Nemko Class - I Certificate
Nemko Class - II Certificate
UL Class - I Certificate
Mechanical Specifications
AC Input Connector (J1)

Molex: 26-60-4030 or equivalent
Mating: 09-50-3031; Pins: 08-50-0106
Pin 1
Pin 2
AC LINE
AC NEUTRAL
DC Ouput Connector (J2) Tyco: 640445-6 or equivalent
Mating: 647402-6; Pins: 3-647409-1
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
V1
V1
RTN
RTN
V3
V2
Signal Connector (J3) Molex: 22-23-2021 or equivalent
Mating: 22-01-2021
Pin 1
Pin 2
+V1 SENSE
-VE SENSE
EARTH (J4)
   Spade Connector
Molex: 19705-4301
Mating: 19003-0001
EARTH
Mechanical Drawing

WLT60- 1XXX

WLT60-1x
Mechanical Drawing

WLT60 - 3XXX

WLT60-3
    General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing

WLT60 (1XXX) WITH BASE PLATE

WLT60-3
    General Notes: In case the PCB is mounted on a metal base plate, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing

WLT60 (3XXX) WITH BASE PLATE

WLT60-4
    General Notes: In case the PCB is mounted on a metal base plate, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing

WLT60 SERIES WITH ‘L’ BRACKET

WLT60-5
    General Notes: In case the PCB is mounted on a metal ‘L’ bracket, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing

WLT60 SERIES WITH ‘U’ CHANNEL

WLT60-6
    General Notes: In case the PCB is mounted in a metal ‘U’ channel, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing

WLT60 SERIES WITH COVER KIT

WLT60-7
    General Notes: In case the PCB is mounted in a metal cover kit, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Safety Certificate
CB Class - I Certificate
CB Class - II Certificate
Nemko Class - I Certificate
Nemko Class - II Certificate
UL Class - I Certificate

Related Products