WLT40
The EOS Power Economical Green Series was designed with the value focused customer in mind. The WLT Green Series offers market leading specifications in industry standard footprints at very competitive price levels.
FEATURES
- 40 W convection cooled rating.
- Small 4.0”x2.0”x1.2” inch form factor.
- High efficiency > 85 %.
- Single to triple outputs.
- Low conducted and radiated noise.
- No Load Power< 0.3 W
- Class I & Class II options.
- Cover Kit accessory available.
- Now IEC/EN/UL62368-1 CompliantNEW
- Approved with metal enclosures/accessories
Input Specifications
Input Voltage | 90-264 V, Universal                                                                                                 | |
Input Frequency4 | 47-400Hz | |
Input Current | 0.85 A max @ 120 VAC AND 0.45 A max @ 230 VAC | |
No Load Power | < 0.3W for single output models < 0.5W for multi output models |
|
Inrush Current | 30 A max @ 120 VAC AND 60 A max @ 230 VAC |
Output Specifications
Output Voltage | From 5 V to 58 V (Refer model number matrix table)     | |
Output Power | 40 W | |
Hold-up Time | >10 ms @ 120 VAC typical | |
Line Regulation | +/-0.3 % | |
Load Regulation | V1: +/-0.5 %; V2 & V3: +/-5 % | |
Minimum Load | Refer model number matrix table. | |
Transient Response | max excursion 10 %; 50-100 % step load change at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms. | |
Ripple1 | Refer model number matrix table. | |
Rise Time | < 100 ms | |
Set Point Tolerance | V1: +/-3 %; V2 & V3: +/-5 % | |
Output Voltage Adjustment | V1:+/- 10 % | |
Over Current Protection | 130 % typical above rating | |
Over Voltage Protection | 130 % typical for V1 only | |
Short Circuit Protection | Short term, auto recovery | |
Cooling | Convection |
General Specifications
Efficiency5 | 120 VAC: 85 % typical AND 230 VAC: 85 % typical                                                                   | |
Isolation Voltage | Input to Output 4000 VAC/VDC | |
MTBF | 1.87m Hours, Telcordia -SR332-issue 3 | |
Switching Frequency | Approximately 67 kHz | |
Leakage Current | 120 VAC: < 500 μA AND 230 VAC: < 1000 μA | |
Dimensions | 4.0 x 2.0 x 1.2 inches (101.6 x 50.8 x 30.48 mm) |
|
Weight | 150 gm approx |
Environmental Specifications
Operating Temperature | -20 to 70°C, refer derating curve,-20 to 0°C,startup is guaranteed                                                                  | |
Storage Temperature | -40 to +70°C | |
Relative Humidity | 95 % Rh, non condensing | |
Altitude | Operating: 10,000 ft.; Non-operating: 40,000 ft |
Model Number | Power Supply Unit & its Installation Type |
Maximum Wattage | Voltage | Max.Load2 | Min. Load5 | Ripples3 |
LFWLT40-1000-CK | In CK cover Kit | 40W | V1=5 V | 8.0 A | 0.00 A | 1.00% |
LFWLT40-1000 | In Open Frame | |||||
LFWLT40-1000-L | With L Bracket | |||||
LFWLT40-1000-B | With Base Plate | |||||
LFWLT40-1000-U | With U channel | |||||
LFWLT40-1001-CK | In CK cover Kit | 40W | V1=12 V | 3.5 A | 0.00 A | 1% |
LFWLT40-1001 | In Open Frame | |||||
LFWLT40-1001-L | With L Bracket | |||||
LFWLT40-1001-B | With Base Plate | |||||
LFWLT40-1001-U | With U channel | |||||
LFWLT40-1002-CK | In CK cover Kit | 40W | V1=15 V | 2.7 A | 0.0 A | 1.00% |
LFWLT40-1002 | In Open Frame | |||||
LFWLT40-1002-L | With L Bracket | |||||
LFWLT40-1002-B | With Base Plate | |||||
LFWLT40-1002-U | With U channel | |||||
LFWLT40-1003-CK | In CK cover Kit | 40W | V1=24 V | 1.7 A | 0.00 A | 1% |
LFWLT40-1003 | In Open Frame | |||||
LFWLT40-1003-L | With L Bracket | |||||
LFWLT40-1003-B | With Base Plate | |||||
LFWLT40-1003-U | With U channel | |||||
LFWLT40-1004-CK | In CK cover Kit | 40W | V1=48 V | 0.83 A | 0.00 A | 1.00% |
LFWLT40-1004 | In Open Frame | |||||
LFWLT40-1004-L | With L Bracket | |||||
LFWLT40-1004-B | With Base Plate | |||||
LFWLT40-1004-U | With U channel | |||||
LFWLT40-3000-CK | In CK cover Kit | 40W | V1=5.2 V V2=12.5 V V3=-12.8 V | V1=6.0 A V2=2.0 A V3=0.5 A | V1=0.5 A V2=0.1 A V3=0.0 A | V1=1.5 %, V2 & V3=1 % |
LFWLT40-3000 | In Open Frame | |||||
LFWLT40-3000-L | With L Bracket | |||||
LFWLT40-3000-B | With Base Plate | |||||
LFWLT40-3000-U | With U channel | |||||
LFWLT40-3001-CK | In CK cover Kit | 40W | V1=5.2 V V2=24 V V3=-12.8 V | V1=6.0 A V2=1.0 A V3=0.5 A | V1=0.5 A V2=0.1 A V3=0.0 A | V1=1.5 %, V2 & V3=1 % |
LFWLT40-3001 | In Open Frame | |||||
LFWLT40-3001-L | With L Bracket | |||||
LFWLT40-3001-B | With Base Plate | |||||
LFWLT40-3001-U | With U channel | |||||
LFWLT40-3002-CK | In CK cover Kit | 40W | V1=5.2 V V2=15 V V3=-15 V | V1=6.0 A V2=1.5 A V3=0.5 A | V1=0.5 A V2=0.1 A V3=0.0 A | V1=1.5 %, V2 & V3=1 % |
LFWLT40-3002 | In Open Frame | |||||
LFWLT40-3002-L | With L Bracket | |||||
LFWLT40-3002-B | With Base Plate | |||||
LFWLT40-3002-U | With U channel | |||||
LFWLT40-3003-CK | In CK cover Kit | 40W | V1=3.3 V V2=5 V V3=-12.8 V | V1=6.0 A V2=3.0 A V3=0.5A | V1=1.0 A V2=0.1 A V3=0.0 A | V1=1.5 %, V2 & V3=1 % |
LFWLT40-3003 | In Open Frame | |||||
LFWLT40-3003-L | With L Bracket | |||||
LFWLT40-3003-B | With Base Plate | |||||
LFWLT40-3003-U | With U channel | |||||
LFWLT60-CK metal cover kit accessory |
- Specifications are for nominal input voltage, 25°C and max. load unless otherwise stated.
- Derate output power linearly to 80% from 90 VAC to 80 VAC input.
- Please refer mechnical outline drawing for height of component above and below PCB for - 1xxx and 3xxx.
- Class II version available. Add "-2" suffix at the end of the Model Number to Order. Enquire with EOS Sales Rep before Order.
-
Notes:
- Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
- Min Load specified to meet cross regulation.
- Maximum current per output channel. Do not exceed total output power rating.
- Safety approved 47-63 Hz.
- For WLT40-3003 efficiency is 75 % typical.
Derating Curve

De-rate linearly from 100 % at 50°C to 75 % at 70°C
EMC
Parameter | Conditions/Description | Criteria |
Conducted Emissions | EN55032-B, CISPR22-B, FCC PART15-B | Pass |
Radiated Emissions | EN 55032 B | Pass |
Input Current Harmonics | EN 61000-3-2 | Class A |
Voltage Fluctuation and Flicker | EN 61000-3-3 | Pass |
ESD Immunity | EN 61000-4-2 | Level 3, Criterion A |
Radiated Field Immunity | EN 61000-4-3 | Level 3, Criterion A |
Electrical Fast Transient Immunity | EN 61000-4-4 | Level 3, Criterion A |
Surge Immunity | EN 61000-4-5 | Level 3, Criterion A |
Conducted Immunity | EN 61000-4-6 | Level 3, Criterion A |
Magnetic Field Immunity | EN 61000-4-8 | Level 3, Criterion A |
Voltage dips, interruptions | EN 61000-4-11 | Criterion A & B |
Safety
CE Mark | Complies with LVD Directive |
Safety Standard(s) |
IEC60950-1(ed.2), EN 60950-1, UL60950-1 (2nd Edition),CSA C22.2 No. 60950-1 (2nd Edition),UL 62368-1, 2nd Ed, 2014-12-01 CAN/CSA C22.2 No. 62368-1-14, (2nd Edition), Class1 SELV IEC 62368-1:2014 ,EN 62368-1:2014 ;A11 |
Approval Agency | Nemko, UL, C-UL |
Safety File Number(s) |
Class I UL: Certificate Number: E150565, 20190628-E150565 Nemko: Certificate No: P13216531, CB Test Certificate No: NO72727 Nemko: Certificate No: P19223597, CB Test Certificate No: NO106818 Class II UL: Certificate Number: E150565, Nemko: Certificate No: P13216532, CB Test Certificate No: NO72729 |
Mechanical Specifications
AC Input Connector (J1)
|
Molex: 26-60-4030 or equivalent Mating: 09-50-3031; Pins: 08-50-0106 |
Pin 1 Pin 2 |
AC LINE AC NEUTRAL |
DC Ouput Connector (J2) | Tyco: 640445-6 or equivalent Mating: 647402-6; Pins: 3-647409-1 |
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 |
V1 V1 RTN RTN V3 V2 |
Signal Connector (J3) | Molex: 22-23-2021 or equivalent Mating: 22-01-2021 |
Pin 1 Pin 2 |
+V1 SENSE -VE SENSE |
EARTH (J4)     Spade Connector |
Molex: 19705-4301 Mating: 19003-0001 |
EARTH |
Mechanical Drawing
WLT40 - 1XXX

Mechanical Drawing
WLT40 - 3XXX

-
General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLT40 (1XXX) WITH BASE PLATE

-
General Notes: In case the PCB is mounted on a metal base plate, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLT40 (3XXX) WITH BASE PLATE

-
General Notes: In case the PCB is mounted on a metal base plate, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLT40 SERIES WITH ‘L’ BRACKET

-
General Notes: In case the PCB is mounted on a metal ‘L’ bracket, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLT40 SERIES WITH ‘U’ CHANNEL

-
General Notes: In case the PCB is mounted in a metal ‘U’ channel, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLT40 SERIES WITH COVER KIT

-
General Notes: In case the PCB is mounted in a metal cover kit, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.