WLT300
The EOS Power Economical Green Series was designed with the value focused customer in mind. The WLT Green Series offers market leading specifications in industry standard footprints at very competitive price levels.
- Electrical Specifications
- Signals
- Derating Curve
- EMC & Safety
- Mechanical Specifications
- Certificates
Input Specifications
Input Voltage | 90-264 VAC/120-390 VDC, Universal                                                       | |
Input Frequency | 47-63 Hz | |
Input Current | 3.2 A max @ 120 VAC AND 1.65 A max @ 230 VAC | |
Inrush Current | 35 A max @ 120 VAC AND 65 A max @ 230 VAC |
Output Specifications
Output Voltage | From 5 V to 48 V (Refer model number matrix table) | |
Output Power | 200 to 325 W | |
Hold-up Time | 120 VAC: 10 ms AND 230 VAC: 10 ms | |
Line Regulation | +/-0.5 % | |
Load Regulation | +/-2.0 % | |
Minimum Load | 0.0 A | |
Transient Response | max excursion 10 %; 50 % to 100 % load at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms. | |
Ripple1 | 2.0 % max for all outputs. | |
Rise Time | < 100 ms | |
Set Point Accurarcy | +/-1 % | |
Output Voltage Adjustment | +/-3 % | |
Over Current Protection | 110 to 150 % | |
Over Voltage Protection | 110 to 150 %, auto recovery | |
Short Circuit Protection | Short term, auto recovery | |
Over Temperature Protection | 110°C primary heat sink, auto recovery | |
Cooling | Convection: up to 140W max (5V model), Up to 200W max (12V, 15V, 24V, 30V and 48V models) With 300LFM : up to 200W max (5V model), Up to 300W max (12V and 15V models), Up to 325W max (24V, 30V and 48V models) Refer de-rating curves to determine output power over the entire operating temperature range. |
General Specifications
Efficiency | 120 VAC: 88 % typical 230 VAC: 92 % typical                                                                                | |
Power Factor | 120 VAC: 0.98 AND 230 VAC: 0.95 | |
Isolation Voltage | Input to Output 4000 VAC/VDC | |
MTBF | 1.77m Hours, Telcordia -SR332-issue 3 | |
Switching Frequency | PFC converter: Fixed, 80 kHz typical Resonant converter: Variable, 35-250 kHz; 90 kHz typical |
|
Leakage Current | 120 VAC: < 125 μA AND 230 VAC: < 250 μA | |
Dimensions | 3 x 5 x 1.5 inches (76.2 x 127 x 38 mm) |
|
Weight | 450 gm |
Environmental Specifications
Operating Temperature | -20 to +70°C, refer derating curve, -20 to 0°C, start-up is guaranteed                                                                  | |
Storage Temperature | -40 to +85°C | |
Relative Humidity | 95 % Rh, non condensing | |
Altitude | Operating: 10,000 ft.; Non-operating: 40,000 ft |
Model Number | Power Supply Unit & its Installation Type |
Power | Voltage | Max. Load2
(Convection) |
Max. Load2 (300 LFM) |
LFWLT300-1000-CK | In CK cover Kit | 98 W | 5 V | 19.6 A | - |
LFWLT300-1000 | In Open Frame | 200 W | 5 V | 28.0 A | 40.0 A |
LFWLT300-1000-L | With L Bracket | 200 W | 5 V | 28.0 A | 40.0 A |
LFWLT300-1000-B | With Base Plate | 200 W | 5 V | 28.0 A | 40.0 A |
LFWLT300-1000-U | With U channel | 200 W | 5 V | 28.0 A | 40.0 A |
LFWLT300-1001-CK | In CK cover Kit | 140 W | 12 V | 11.67 A | - |
LFWLT300-1001 | In Open Frame | 300 W | 12 V | 16.67 A | 25.0 A |
LFWLT300-1001-L | With L Bracket | 300 W | 12 V | 16.67 A | 25.0 A |
LFWLT300-1001-B | With Base Plate | 300 W | 12 V | 16.67 A | 25.0 A |
LFWLT300-1001-U | With U channel | 300 W | 12 V | 16.67 A | 25.0 A |
LFWLT300-1002-CK | In CK cover Kit | 140 W | 15 V | 9.33 A | - |
LFWLT300-1002 | In Open Frame | 300 W | 15 V | 13.33 A | 20.0 A |
LFWLT300-1002-L | With L Bracket | 300 W | 15 V | 13.33 A | 20.0 A |
LFWLT300-1002-B | With Base Plate | 300 W | 15 V | 13.33 A | 20.0 A |
LFWLT300-1002-U | With U channel | 300 W | 15 V | 13.33 A | 20.0 A |
LFWLT300-1003-CK | In CK cover Kit | 140 W | 24 V | 5.83 A | - |
LFWLT300-1003 | In Open Frame | 325 W | 24 V | 8.33 A | 13.54 A |
LFWLT300-1003-L | With L Bracket | 325 W | 24 V | 8.33 A | 13.54 A |
LFWLT300-1003-B | With Base Plate | 325 W | 24 V | 8.33 A | 13.54 A |
LFWLT300-1003-U | With U channel | 325 W | 24 V | 8.33 A | 13.54 A |
LFWLT300-1004-CK | In CK cover Kit | 140 W | 48 V | 2.92 A | - |
LFWLT300-1004 | In Open Frame | 325 W | 48 V | 4.17 A | 6.77 A |
LFWLT300-1004-L | With L Bracket | 325 W | 48 V | 4.17 A | 6.77 A |
LFWLT300-1004-B | With Base Plate | 325 W | 48 V | 4.17 A | 6.77 A |
LFWLT300-1004-U | With U channel | 325 W | 48 V | 4.17 A | 6.77 A |
LFWLT300-1005-CK | In CK cover Kit | 140 W | 30 V | 4.67 A | - |
LFWLT300-1005 | In Open Frame | 325 W | 30 V | 6.67 A | 10.83 A |
LFWLT300-1005-L | With L Bracket | 325 W | 30 V | 6.67 A | 10.83 A |
LFWLT300-1005-B | With Base Plate | 325 W | 30 V | 6.67 A | 10.83 A |
LFWLT300-1005-U | With U channel | 325 W | 30 V | 6.67 A | 10.83 A |
LFWLT300-CK metal cover kit accessory available. |
General Notes:
- Peak current rating on main output is 120 % of max., lasting < 30 s with a maximum 10 % duty cycle.
- Combined output power of main output, fan supply and standby supply shall not exceed max. power rating.
- Standby output voltage tolerance including set point accuracy, line and load regulation is +/-10 %. Ripple and noise is less than 5 %.
- Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-30 % and needs min. 1 % load on main output to be within regulation band. Ripple and noise is less than 10 %.
- Specifications are for nominal input voltage, 25°C unless otherwise stated.
- PSU is supplied with J3 housing, pin-1 and pin-2 shorted to enable main output without remote on/off feature.
- Derate output power linearly to 80% from 90 VAC to 80 VAC input.
- Power good signal cannot be used as a current source. Internal pull up resistor from PG signal to 5V is 10K. It is recommended to use external transistor if intended to source current.
- The de-rating curves are valid for input voltages of 115VAC to 264 VAC. Below 115VAC to 90VAC the convection rating is 180 Watts maximum.
- When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
-
Notes:
- 1. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
Signals
Power Good Signal | TTL signal goes high after main output reaches 90% of its final set value, delay is 0.1 to 0.5 s. |
Remote Sense | Compensates for 200 mV drop. |
Remote on/off | To turn-on PSU short remote pin to ground. |
Derating Curve
Convection load: 140W up to 40 °C De-rate between 40 °C @ 1.67 % per °C Forced air cooled load : 200W up to 40°C De-rate above 40 °C @ 1.67 % per °C |
|
Convection load: 200W up to 40 °C De-rate between 40-50 °C @ 1 % per °C De-rate between 50 °C @ 2.5 % per °C Forced air cooled load : 300 W up to 50°C De-rate above 50 °C @ 2.5 % per °C |
|
Convection load: 200W up to 40 °C De-rate between 40-50 °C @ 1 % per °C De-rate between 50 °C @ 2.5 % per °C Forced air cooled load : 325 W up to 50°C De-rate above 50 °C @ 2.5 % per °C |
EMC
Parameter | Conditions/Description | Criteria |
Conducted Emissions | EN55032-B, CISPR22-B, FCC PART15-B | Pass |
Radiated Emissions | EN 55032 A |
Pass Level B with external core (King core K5B RC 25x12x15-M in input cable) |
Input Current Harmonics | EN 61000-3-2 | Class D |
Voltage Fluctuation and Flicker | EN 61000-3-3 | Pass |
ESD Immunity | EN 61000-4-2 | Level 3, Criterion A |
Radiated Field Immunity | EN 61000-4-3 | Level 3, Criterion A |
Electrical Fast Transient Immunity | EN 61000-4-4 | Level 3, Criterion A |
Surge Immunity | EN 61000-4-5 | Level 3, Criterion A |
Conducted Immunity | EN 61000-4-6 | Level 3, Criterion A |
Magnetic Field Immunity | EN 61000-4-8 | Level 3, Criterion A |
Voltage dips, interruptions | EN 61000-4-11 | Criterion A & B |
Safety
CE Mark | Complies with LVD Directive |
Safety Standard(s) | IEC 62368-1:2014, EN 62368-1:2014;A11 , UL 62368-1 and CAN/CSA C22.2 No. 62368-1-14 |
Approval Agency | Nemko, UL |
Safety File Number(s) | CB Certificate No: NO107429, Nemko Certificate No: P19223724, UL Certificate Number: 20191011-E150565 |
Mechanical Specifications
AC Input Connector (J1) | Molex: 26-60-4030 or equivalent Mating: 09-50-3031; Pins: 08-50-0106 |
Pin 1 Pin 2 |
AC LINE AC NEUTRAL |
DC Ouput Connector (J2) | 6-32 inches Screw Pan HD Mating: Designed to accept Ring Tongue Terminal AMP : 8-31886-1, wherein one 16 AWG(max) wire can be crimped. Note : One Ring Tongue Terminal with 16 AWG is recommended for current up to 11A only. Use multiple tongue terminals with wire for more current. |
Pin 1 Pin 2 |
RTN V1 |
Fan Connector (J3) | Molex: 22-23-2081 or equivalent Mating: 22-01-2087, Pins: 08-50-0113 |
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 |
REMOTE ON/OFF RTN VFAN (+12 V/0.5 A) -VE REMOTE SENSE VSTBY (+5 V/2 A, +/-5%) +VE REMOTE SENSE RTN POWER GOOD |
EARTH (J4) Spade Connector |
Molex: 19705-4301 Mating: 190030001 | EARTH |
Mechanical Drawing
WLT300 SERIES WITH 'L' BRACKET
WLT300 SERIES WITH BASE PLATE
WLT300 SERIES WITH 'U' CHANNEL
WLT300 SERIES WITH COVER KIT
-
General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following.
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.