WLP75
WLP Blue Series offers the size conscious customer industry leading watts per cubic inch in height profiles ranging from 25 mm to 30 mm in industry standard footprints. The Blue Series allows customers shrink their applications without compromising on power, quality or functionality.
FEATURES
- 3 x 2 x 1 Inches Form factor
- 75 Watts Convection
- Efficiencies up to 93 %
- Fulfils EN 62368-1:2014 +A11:2017
- -40 to 70 degree operating temperature
- Now IEC/UL62368-1:2018 CompliantNEW
- Thermal Shut-Down feature
- 2.00m Hours, Telcordia-SR332-issue 3
- No Load Power < 0.3W
- Approved with metal enclosures/accessories
Input Specifications
Input Voltage                   | 85-264 VAC/390 VDC3, Universal (Derate from 75W at 100V AC to 65W at 85V AC) | |
Input Frequency | 47-63 Hz | |
Input Current | 1 A max @ 115 VAC AND 0.5 A max @ 230 VAC | |
No Load Power | less than 0.3W typical | |
Inrush Current | 25 A @ 115 VAC; 45 A @ 230 VAC; 75 A @ 264 VAC |
Output Specifications
Output Voltage | From 12V to 58V (See model number matrix table) | |
Output Power | 75 W Convection | |
Output Voltage Adjustability | +/-3 % | |
Hold-up Time | >16 ms typical | |
Line Regulation | +/-0.5 % | |
Load Regulation | +/-1 % | |
Minimum Load | 0.0 A | |
Transient Response | max excursion 4 %; 25 % step load change at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms. | |
Ripple1 | 1.0 % max for all outputs. | |
Rise Time | 55 ms typical | |
Set Point Tolerance | +/-1 % | |
Over Current Protection | Typ 110 % | |
Over Voltage Protection | 110 to 140 %, Latch type (AC recycling required) | |
Short Circuit Protection | Hiccup mode | |
Cooling | 75W with natural convection cooling at 100 to 264 VAC. |
General Specifications
Efficiency | 93 % (48V,58V). 91 % (24V,30V), 90 % (12V,15V)                                                                  | |
Isolation Voltage | Input to Output – 4000 VAC for ITE application Input to GND - 2500 VAC |
|
MTBF | 2.00m Hours, Telcordia-SR332-issue 3 | |
Switching Frequency | 60 KHz typical | |
Power Factor | Exceeds 0.95 with Full Load | |
Dimensions | 3 x 2 x 1 inches (76.2 x 50.8 x 25.4 mm) |
|
Weight | 150 gm approx |
Environmental Specifications
Operating Temperature | - 40 to +70°C, (-40 to 0°C startup is guaranteed with spec deviation)2                                    | |
Storage Temperature | -40 to +85°C | |
Relative Humidity | 5 % to 95 %, noncondensing | |
Altitude | Operating: 16,000 ft.; Non-operating: 40,000 ft |
Model Number | Power Supply Unit & its Installation Type |
Power | Voltage | Max. Load
(Convection) |
LFWLP75-1X01-CK | In CK cover Kit | 52.5 W | 12 V | 4.38 A |
LFWLP75-1X01 | In Open Frame | 75 W | 12 V | 6.25 A |
LFWLP75-1X01-L | With L Bracket | |||
LFWLP75-1X01-B | With Base Plate | |||
LFWLP75-1X01-U | With U channel | |||
LFWLP75-1X02-CK | In CK cover Kit | 52.5 W | 15 V | 3.50 A |
LFWLP75-1X02 | In Open Frame | 75 W | 15 V | 5.00 A |
LFWLP75-1X02-L | With L Bracket | |||
LFWLP75-1X02-B | With Base Plate | |||
LFWLP75-1X02-U | With U channel | |||
LFWLP75-1X03-CK | In CK cover Kit | 52.5 W | 24 V | 2.18 A |
LFWLP75-1X03 | In Open Frame | 75 W | 24 V | 3.12 A |
LFWLP75-1X03-L | With L Bracket | |||
LFWLP75-1X03-B | With Base Plate | |||
LFWLP75-1X03-U | With U channel | |||
LFWLP75-1X04-CK | In CK cover Kit | 52.5 W | 48 V | 1.09 A |
LFWLP75-1X04 | In Open Frame | 75 W | 48 V | 1.56 A |
LFWLP75-1X04-L | With L Bracket | |||
LFWLP75-1X04-B | With Base Plate | |||
LFWLP75-1X04-U | With U channel | |||
LFWLP75-1X05-CK | In CK cover Kit | 52.5 W | 30 V | 1.75 A |
LFWLP75-1X05 | In Open Frame | 75 W | 30 V | 2.50 A |
LFWLP75-1X05-L | With L Bracket | |||
LFWLP75-1X05-B | With Base Plate | |||
LFWLP75-1X05-U | With U channel | |||
LFWLP75-1X06-CK | In CK cover Kit | 52.5 W | 58 V | 0.90 A |
LFWLP75-1X06 | In Open Frame | 75 W | 58 V | 1.29 A |
LFWLP75-1X06-L | With L Bracket | |||
LFWLP75-1X06-B | With Base Plate | |||
LFWLP75-1X06-U | With U channel | |||
For Screw Terminal version replace "X" above with "0" (examples: LFWLP75-1005) For Header version replace "X" above with "3" (examples: LFWLP75-1305) | ||||
LFWLP120/75-CK metal cover kit accessory available. |
General Notes:
- Specifications are for nominal input voltage, 25°C unless otherwise stated.
- When used in Cover Kit, de-rate output power to 70 % under all operating conditions
- For Class II version Enquire with EOS Sales Rep before Order.
- Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage AND load ranges.
- Output ripple can be more than 10% of the output voltage.
- Functional,not approved.
Derating Curve
Convection load: 75W up to 50°C De-rate above 50 °C @ 2.5% per °C |
|
Convection load: 52.5W up to 50 °C De-rate above 50 °C @ 2.5% per °C |
EMC
Parameter | Conditions/Description | Criteria |
Conducted Emissions | EN55032-B, CISPR22-B, FCC PART15-B | Pass |
Radiated Emissions | EN 55032 A |
Pass Level B with external core (King core K5B RC 25x12x15-M in input cable) |
Input Current Harmonics | EN 61000-3-2 | Class D |
Voltage Fluctuation and Flicker | EN 61000-3-3 | Pass |
ESD Immunity | EN 61000-4-2 | Level 3, Criterion A |
Radiated Field Immunity | EN 61000-4-3 | Level 3, Criterion A |
Electrical Fast Transient Immunity | EN 61000-4-4 | Level 3, Criterion A |
Surge Immunity | EN 61000-4-5 | Level 3, Criterion A |
Conducted Immunity | EN 61000-4-6 | Level 3, Criterion A |
Magnetic Field Immunity | EN 61000-4-8 | Level 3, Criterion A |
Voltage dips, interruptions | EN 61000-4-11 | Criterion A & B |
Safety
CE Mark | Complies with LVD Directive |
Safety Standard(s) |
IEC 62368-1:2018, EN 62368-1:2014;A11, UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19 |
Approval Agency | Nemko, UL, C-UL, CCC |
Safety File Number(s) |
CB Test Certificate No :NO110826 , Nemko Certificate No: P20224328 , UL Certificate No: E515384 , |
Environmental
RoHS Version | LFWLP75 series meet RoHS Compliance as per european RoHS directive (Directive 2011 / 65 / EU) |
Mechanical Specifications
AC Input Connector (J1) Option 1 |
Molex: 39357-0003 Tyco: 2-1776112-3 |
Pin 1 Pin 2 Pin 3 |
AC LINE NOT FITTED AC NEUTRAL |
AC Input Connector (J1) Option 2 |
Molex:1722861103 (Mating conn: Molex 1722561003) (Mating conn: Molex 1722561103) (Mating conn: Molex 1722563103) |
Pin 1 Pin 2 Pin 3 |
AC LINE NOT FITTED AC NEUTRAL |
DC Output Connector (J2)) Option 1 |
Molex: 39357-0004 Tyco: 2-1776112-4 |
Pin 1,2 Pin 3,4 |
V1 -VE V1 +VE |
DC Output Connector (J2) Option 2 |
Molex:1722861104 (Mating conn: Molex 1722561004) (Mating conn: Molex 1722561104) (Mating conn: Molex 1722563104) |
Pin 1,2 Pin 3,4 |
V1 -VE V1 +VE |
Screw Terminal
Tyco Header
-
General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
-
General Notes: In case the PCB is mounted on a metal base plate, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
-
General Notes: In case the PCB is mounted on a metal ‘L’ bracket, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
-
General Notes: In case the PCB is mounted on a metal ‘U’ Channel, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
-
General Notes: In case the PCB is mounted in a metal cover kit, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.