Inquiry

WLP120

BLUE SERIES
WLP120

WLP Blue Series offers the size conscious customer industry leading watts per cubic inch in height profiles ranging from 25 mm to 30 mm in industry standard footprints. The Blue Series allows customers shrink their applications without compromising on power, quality or functionality.

FEATURES
  • 3” x 2” foot print.
  • Height 1” above PCB.
  • 120 Watts with Forced Air Cooling.
  • Efficiencies up to 93 %.
  • -40 to 70°C operating temperature.
  • Thermal Shut-Down feature.
  • Now IEC/UL62368-1:2018 CompliantNEW
  • Fulfils EN 62368-1:2014 +A11:2017
  • >3.00m Hours, Telcordia-SR332-issue 3.
  • No Load Power < 0.3W.
  • Approved with metal enclosures/accessories
AVAILABLE WITH COVER KIT
WLP120_Coverkit

WLP120-CK Series


Input Specifications
Input Voltage 85-264 VAC/390 VDC3, Universal (see derating under output power)          
Input Frequency 47-63 Hz
Input Current 1.2 A max @ 115 VAC and 0.65 A max @ 230 VAC
No Load Power less than 0.3W typical
Inrush Current 25 A @ 115 VAC; 45 A @ 230 VAC; 75 A @ 264 VAC
Output Specifications
Output Voltage From 12 V to 58 V (Refer model number matrix table)                                                                                                       
Output Power Forced cooling : 120W with 300LFM (refer mechnical drawing)
Convection cooling : 100W (for input 100-264 VAC) & (de-rate linearly to 80W @ 85VAC)
Output Voltage Adjustability +/-3 %
Hold-up Time >10 ms typical
Line Regulation +/-0.5 %
Load Regulation +/-1 %
Minimum Load 0.0 A
Transient Response max excursion 4 %; 25 % step load change at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms.
Ripple1 1.0 % max for all outputs.
Rise Time 55 ms typical
Set Point Tolerance +/-1 %
Over Current Protection Typ 110 %
Over Voltage Protection 110 to 140 %, Latch type (AC recycling required)
Short Circuit Protection Hiccup mode
Cooling up to 120W with 300LFM Forced cooling (refer mechnical drawing)
up to 100W Convection cooling (for input 100-264 VAC)
(de-rate linearly to 80W @ 85VAC)
General Specifications
Efficiency 93 % (48V,58V),91 % (24V,30V),90 % (12V,15V)                                                                
Isolation Voltage Input to Output – 4000 VDC for ITE application
Input to GND - 2500 VDC
MTBF >3.00m Hours, Telcordia -SR332-issue 3
Switching Frequency 60 KHz typical
Power Factor Exceeds 0.95 with Full Load
Dimensions 3 x 2 x 1.18 inches
(76.2 x 50.8 x 30.1mm)
Weight 150 gm approx
Environmental Specifications
Operating Temperature - 40 to +70°C, (-40 to 0°C startup is guaranteed with spec deviation)2                                                
Storage Temperature -40 to +85°C
Relative Humidity 5 % to 95 %, noncondensing
Altitude Operating: 16,000 ft.; Non-operating: 40,000 ft
Model Number Power Supply Unit &
its Installation Type
Power Voltage Max. Load
(Convection)
Max. Load
(300 LFM)
LFWLP120-1X01-CKIn CK cover Kit70 W12 V5.83 A-
LFWLP120-1X01In Open Frame

120 W


12 V


8.33 A


10.0 A
LFWLP120-1X01-LWith L Bracket
LFWLP120-1X01-BWith Base Plate
LFWLP120-1X01-UWith U channel
LFWLP120-1X02-CKIn CK cover Kit70 W15 V4.66 A-
LFWLP120-1X02In Open Frame

120 W


15 V


6.66 A


8.0 A
LFWLP120-1X02-LWith L Bracket
LFWLP120-1X02-BWith Base Plate
LFWLP120-1X02-UWith U channel
LFWLP120-1X03-CKIn CK cover Kit70 W24 V2.91 A-
LFWLP120-1X03In Open Frame

120 W


24 V


4.16 A


5.00 A
LFWLP120-1X03-LWith L Bracket
LFWLP120-1X03-BWith Base Plate
LFWLP120-1X03-UWith U channel
LFWLP120-1X04-CKIn CK cover Kit70 W48 V1.46 A-
LFWLP120-1X04In Open Frame

120 W


48 V


2.08 A


2.5 A
LFWLP120-1X04-LWith L Bracket
LFWLP120-1X04-BWith Base Plate
LFWLP120-1X04-UWith U channel
LFWLP120-1X05-CKIn CK cover Kit70 W30 V2.33 A-
LFWLP120-1X05In Open Frame

120 W


30 V


3.33 A


4.0 A
LFWLP120-1X05-LWith L Bracket
LFWLP120-1X05-BWith Base Plate
LFWLP120-1X05-UWith U channel
LFWLP120-1X06-CKIn CK cover Kit70 W58 V1.20 A-
LFWLP120-1X06In Open Frame

120 W


58 V


1.72 A


2.07 A
LFWLP120-1X06-LWith L Bracket
LFWLP120-1X06-BWith Base Plate
LFWLP120-1X06-UWith U channel
For Screw Terminal version replace "X" above with "0" (examples: LFWLP120-1005)
For Header version replace "X" above with "3" (examples: LFWLP120-1305)
LFWLP120-CK metal cover kit accessory available.
General Notes:
  • Specifications are for nominal input voltage, 25°C unless otherwise stated.
  • When used in Cover Kit, de-rate output power to 70 % under all operating conditions
  • For Class II version Enquire with EOS Sales Rep before Order.
Notes:
  1. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
  2. Output ripple can be more than 10 % of the output voltage.
  3. Functional,not approved.
Derating Curve
WLP120-Derating curve Convection load: 100W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
De-rate between 70 °C to 85°C @ 4% per °C

Forced air cooled load : 120W up to 50°C
De-rate above 50 °C @ 2.5% per °C
De-rate between 70 °C to 85°C @ 4% per °C
WLP120-CK Convection load: 70W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
EMC
Parameter Conditions/Description Criteria
Conducted Emissions EN55032-B, CISPR22-B, FCC PART15-B Pass
Radiated Emissions EN 55032 A Pass
Level B with external core (King core K5B RC 25x12x15-M in input cable)
Input Current Harmonics EN 61000-3-2 Class D
Voltage Fluctuation and Flicker EN 61000-3-3 Pass
ESD Immunity EN 61000-4-2 Level 3, Criterion A
Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A
Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A
Surge Immunity EN 61000-4-5 Level 3, Criterion A
Conducted Immunity EN 61000-4-6 Level 3, Criterion A
Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A
Voltage dips, interruptions EN 61000-4-11 Criterion A & B
Safety
CE Mark Complies with LVD Directive
Safety Standard(s) IEC 62368-1:2018, EN 62368-1:2014;A11, EN 60950-1:2006;A11;A1;A12;A2
UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19, UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07
GB17625.1-2012;GB4943.1-2011;GB/T9254-2008
Approval Agency Nemko, UL, C-UL
Safety File Number(s) CB Test Certificate No: NO110825 , Nemko Certificate No: P20224328 ,
UL Certificate No: E515384
Environmental
RoHS Version LFWLP120 series meet RoHS Compliance as per european RoHS directive
(Directive 2011 / 65 / EU)
Downloads
CB Class - I Certificate
Nemko Class - I Certificate
UL Class - I Certificate
Mechanical Specifications
AC Input Connector (J1)
Option 1
Molex: 39357-0003
Tyco-2-1776112-3
Pin 1
Pin 2
Pin 3
AC LINE
NOT FITTED
AC NEUTRAL
AC Input Connector (J1)
Option 2
Molex:1722861103
(Mating conn: Molex 1722561003)
(Mating conn: Molex 1722561103)
(Mating conn: Molex 1722563103)
Pin 1
Pin 2
Pin 3
AC LINE
NOT FITTED
AC NEUTRAL
DC Output Connector (J2))
Option 1
Molex: 39357-0004
Tyco: 2-1776112-4
Pin 1,2
Pin 3,4
V1 -VE
V1 +VE
DC Output Connector (J2)
Option 2
Molex:1722861104
(Mating conn: Molex 1722561004)
(Mating conn: Molex 1722561104)
(Mating conn: Molex 1722563104)
Pin 1,2
Pin 3,4
V1 -VE
V1 +VE
Screw Terminal
WLP120-1
Tyco Header
WLP120-2
    General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLP120 Base plate mechanical drawing
    General Notes: In case the PCB is mounted on a metal base plate, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLP120 L Bracket mechanical drawing
    General Notes: In case the PCB is mounted on a metal ‘L’ bracket, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLP120 U channel mechanical drawing
    General Notes: In case the PCB is mounted on a metal ‘U’ Channel, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechanical Drawing
WLP120-2
    General Notes: In case the PCB is mounted in a metal cover kit, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Approvals
Certificate Standard Downloads
CB Class - I Certificate IEC 62368-1:2018
Nemko Class - I Certificate EN 62368-1:2014;A11
EN 60950-1:2006;A11;A1;A12;A2
UL Class - I Certificate UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19
UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07

Related Products