Input Specifications
Input Voltage | 90-264 VAC/120-390 VDC, Universal                                                       | |
Input Frequency | 47-63 Hz | |
Input Current | 2.4 A max @ 120 VAC AND 1.2 A max @ 230 VAC | |
Inrush Current | 35 A max @ 120 VAC AND 65 A max @ 230 VAC | |
No Load Power | 0.8W |
Output Specifications
Output Voltage | From 5 V to 48 V (Refer model number matrix table) | |
Output Power | 160 to 200 W | |
Peak Power | 250 W for 0.2 s | |
Hold-up Time | 120 VAC > 10 ms AND 230 VAC > 10 ms | |
Line Regulation | +/-0.5 % | |
Load Regulation | +/-2.0 % | |
Minimum Load | 0.0 A | |
Transient Response | max excursion 10 %; 50% to 100 % load at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms. | |
Ripple1 | 1.0 % max for all outputs. | |
Rise Time | < 100 ms | |
Set Point Accurarcy | +/-1 % | |
Output Voltage Adjustment | +/-3 % | |
Over Current Protection | 110 % typical above rating | |
Over Voltage Protection | 110 to 150 % | |
Short Circuit Protection | Short term, auto recovery | |
Cooling | Convection: 83 W; 300 LFM: Up to 175 W (5 V model), Convection: 160 W; 300 LFM: Up to 200 W (Other model) |
General Specifications
Efficiency | 120 VAC: 84 % typical AND 230 VAC: 86 % typical                                                             | |
Power Factor | 120 VAC: 0.99 AND 230 VAC: 0.95 | |
Isolation Voltage | Min. 5900 VDC between input to output | |
MTBF | 1.6m Hours, Telcordia -SR332-issue 3 | |
Switching Frequency | PFC converter: Variable, 35-250 kHz; 90 kHz typical R esonant converter: Variable, 35-250 kHz; 90 kHz typical |
|
Leakage Current | 120 VAC: < 150 μA AND 230 VAC: < 300 μA | |
Dimensions | 5.0 x 3.0 x 1.5 inches (127 x 76.2 x 38.1 mm) |
|
Weight | 325 gm |
Environmental Specifications
Operating Temperature | -20 to +70°C, refer derating curve,-20 to 0°C,startup is guaranteed                                                  | |
Storage Temperature | -40 to +85°C | |
Relative Humidity | 95 % Rh, non condensing | |
Altitude | Operating: 10,000 ft.; Non-operating: 40,000 ft |
Model Number | Power | Voltage | Max. Load2
(Convection) |
Max. Load2 (300 LFM) |
LFMWLT200-1000 | 175 W | 5 V | 16.67 A | 35.0 A |
LFMWLT200-1300 | 130 W | 5 V | 16.67 A | 26.0 A |
LFMWLT200-1X01 | 200 W | 12 V | 13.33 A | 16.67 A |
LFMWLT200-1X02 | 200 W | 15 V | 10.67 | 13.33 A |
LFMWLT200-1X03 | 200 W | 24 V | 6.67 A | 8.33 A |
LFMWLT200-1X04 | 200 W | 48 V | 3.33 A | 4.17 A |
LFMWLT200-1X05 | 200 W | 30 V | 5.33 A | 6.67 A |
For Screw Terminal version replace "X" above with "0", example LFMWLT200-1003, Class 1 option For Header version (JST Connector) replace "X" above with "3", example LFMWLT200-1303, Class 1 Option. | ||||
LFWLT200-CK metal cover kit accessory available. |
- Fan output voltage tolerance is +/-20 %. During V1 full load, VFAN needs min. 20 mA load to be within regulation band.
- Peak current for fan output is 1 A.
- Class 1 products have an Earthing tab and Class 2 products (-2 suffix) have no Earthing tab.
- Specifications are for nominal input voltage, 25°C and max. load unless otherwise stated.
- Derate output power linearly to 80 % from 90 VAC to 80 VAC input.
- When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
- Class 2 version available, Add "-2" suffix at the end of the Model Number
-
Notes:
- Ripple is 2 % up to 20 % load and < 1 % above 20 % load. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
- Combined output power from V1 and VFAN should not exceed the total output power rating.
Signals
Power Good Signal | TTL signal goes high after main output reaches 90% of its final set value, delay is 0.1 to 0.5 s. |
![]() |
|
Power Fail Signal | TTL signal goes low at least 1ms before output falls to 90% of its set value due to mains failure. |
![]() |
|
Remote Sense | Compensates for 200 mV drop. |
Remote on/off | To turn-on PSU short remote pin to ground. |
Derating Curve
![]() |
Convection load: 83W up to 40 °C De-rate between 40 °C @ 1.89 % per °C Forced air cooled load : 130W up to 50°C (for JST connector version) De-rate above 50 °C @ 1.63 % per °C Forced air cooled load : 175W up to 50°C (for Screw terminal version) De-rate above 50 °C @ 2.5 % per °C |
![]() |
Convection load: 160W up to 40 °C De-rate between 40 °C @ 2% per °C Forced air cooled load : 200 W up to 50°C De-rate above 50 °C @ 2.5 % per °C |
EMC
Parameter | Conditions/Description | Criteria |
Conducted Emissions | EN 55011-B,CISPR22-B, FCC PART15-B | Pass |
Radiated Emissions | EN 55011 B | Pass |
Input Current Harmonics | EN 61000-3-2 | Class D |
Voltage Fluctuation and Flicker | EN 61000-3-3 | Pass |
ESD Immunity | EN 61000-4-2 | Level 4, Criterion A |
Radiated Field Immunity | EN 61000-4-3 | Level 3, Criterion A |
Electrical Fast Transient Immunity | EN 61000-4-4 | Level 3, Criterion A |
Surge Immunity | EN 61000-4-5 | Level 3, Criterion A |
Conducted Immunity | EN 61000-4-6 | Level 3, Criterion A |
Magnetic Field Immunity | EN 61000-4-8 | Level 4, Criterion A |
Voltage dips, interruptions | EN 61000-4-11 | Criterion A & B |
Safety
CE Mark | Complies with LVD Directive |
Safety Standard(s) | EN60601-1, IEC60601-1 (ed.3), ANSI / AAMI ES 60601 - 1, CSA C22.2 No. 60601-1 |
Approval Agency | Nemko, UL, C-UL |
Safety File Number(s) | Class I UL: Certificate Number : E173812, Nemko: Certificate No: P15220606, CB Test Certificate No: NO90000 |
Mechanical Specifications
AC Input Connector (J1)
|
Molex: 26-60-4030 or equivalent Mating: 09-50-3031; Pins: 08-50-0106 |
Pin 1 Pin 2 |
AC NEUTRAL AC LINE |
DC Ouput Connector (J2) | Option-1: Tyco: 1776112-3 or equivalent Mating: 13 AWG wire Option-2: JST: B4P-VH-B (LF) (SN) or B4P-VH (LF) (SN) or equivalent Mating: VHR-4M; Pins: SVH-41T-P1.1 |
Pin 1,2,3 Pin 4,5,6 |
RTN V1 |
Signal Connector (J3) | Molex: 22-23-2081 or equivalent Mating: 22-01-2087, Pins: 08-50-0113 |
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 |
+VE REMOTE SENSE VFAN (+12 V/0.5A) -VE REMOTE SENSE REMOTE ON/OF VSTBY (+5 V/1 A, +/-5 %) RTN POWER FAIL POWER GOOD |
EARTH (J4) Spade Connector |
Molex: 19705-4301 or equivalent Mating: 190030001 |
-- | EARTH |
Mechanical Drawing
-
General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following.
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.