MWLP225
MWLP Blue Series offers the size conscious customer industry leading watts per cubic inch in height profiles ranging from 25 mm to 30 mm in industry standard footprints. The Blue Series allows customers shrink their applications without compromising on power, quality or functionality.
FEATURES
- 4 x 2 x 1 Inches Form factor.
- 225 Watts with Forced Air Cooling..
- 7 Year Extended Warranty Option.
- Efficiencies up to 94 %.
- -40 to 70 degree operating temperature.
- Dual fusing.
- 12V/0.5A Fan Output, Thermal Shut-Down feature .
- 3.37m Hours, Telcordia -SR332-issue 3 MTBF.
- No Load Power < 0.5W.
- Medical (BF) Safety Approvals.
- Meets standard IEC60601-1-2 : 2014 (4th Edition).
-
-
-
-
- *** Available at additional cost to know more Please contact sales.
Input Specifications
Input Voltage | 85-264 VAC/390 VDC, Universal (Derate from 100 % at 100V AC to 95 % at 85V AC)                          |
|
Input Frequency | 47-63 Hz | |
Input Current | 2.2 A max @ 115 VAC AND 1.1 A max @ 230 VAC | |
No Load Power | less than 0.3W typical | |
Inrush Current | 25 A @ 115 VAC; 45 A @ 230 VAC; 75 A @ 264 VAC |
Output Specifications
Output Voltage | From 12V to 58V (Refer model number matrix table)                                                                                                                    | |
Output Power | 225W with 13 CFM, upto 120W Convection | |
Output Voltage Adjustment4 | +/-3 % | |
Hold-up Time | at 225W:10 ms ; 110W: 16 ms | |
Line Regulation | +/-0.5 % | |
Load Regulation | +/-0.5 % | |
Minimum Load | 0.0 A | |
Transient Response | max excursion 4 %; 25 % step load change at 0.1A/uS slew rate, 50 % duty cycle, 50/60Hz, recovery time < 5 ms. | |
Ripple1 | 1.0 % max for all outputs. | |
Rise Time | 55 ms typical | |
Set Point Tolerance | +/-1 % | |
Over Current Protection | >110 % | |
Over Voltage Protection | 110 to 140 % | |
Short Circuit Protection | Hiccup mode | |
Cooling |
up to 225W with with 13 CFM forced air cooling2(refer Mechanical Drawing) upto 120 W with natural convection cooling2(refer Derating Curve) |
General Specifications
Efficiency | 94 % (48V), 93 % (24V,30V), 92 % (12V,15V)                                                                                   | |
Isolation Voltage | Input to Output – 4000 VAC medical applications. Input to GND - 1500 VAC (Not Applicable For Class II Option) Output to GND- 1500VAC for type BF , 500 VAC for type B (Not Applicable For Class II Option) |
|
MTBF | 3.37m Hours, Telcordia -SR332-issue 3 | |
Switching Frequency | PFC – 70 to 130 KHz ,PWM – 50-80 KHz | |
Power Factor | Exceeds 0.95 with Full Load | |
Leakage Current | 300 uA Typical, (N.A. For Class II Option) Touch current <100uA | |
Dimensions | 4 x 2 x 1 inches (101.60 x 50.8x 25.4 mm) |
|
Weight | 200 gm approx |
Environmental Specifications
Operating Temperature | - 40 to +70°C, (-40 to 0°C startup is guaranteed with spec deviation)3                                                              | |
Storage Temperature | -40 to +85°C | |
Relative Humidity | 5 % to 95 %, noncondensing | |
Altitude | Operating: 16,000 ft.; Non-operating: 40,000 ft |
Model Number | Power | Voltage | Max. Load
(Convection) (112.5 W)50˚C |
Max. Load
(Convection) (120 W) 40˚C |
Max. Load (13 CFM) (225 W) |
LFMWLP225-1X01 | 225 W | 12 V | 9.37 A | 10.0 A | 18.75 A |
LFMWLP225-1X02 | 225 W | 15 V | 7.5 A | 8.0 A | 15.0 A |
LFMWLP225-1X03 | 225 W | 24 V | 4.68 A | 5.0 A | 9.37 A |
LFMWLP225-1X04 | 225 W | 48 V | 2.34 A | 2.5 A | 4.68 A |
LFMWLP225-1X05 | 225 W | 30 V | 3.75 A | 4.0 A | 7.5 A |
LFMWLP225-1X06 | 225 W | 58 V | 1.94 A | 2.07 A | 3.88 A |
For Screw Terminal version replace "X" above with "0", example LFMWLP225-1005 For Header version replace "X" above with "3", example LFMWLP225-1305 | |||||
LFWLP225-CK metal cover kit accessory available. | |||||
To order extended warranty product add the suffix –EX to your required part number5, example - LFMWLP225-1001-EX (See Note 5) |
General Notes:
- Combined output power of main output, fan supply shall not exceed max. Power rating.
- Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-15 % and Ripple and noise is less than 10 %.
With V1 fully loaded, Vfan need to have min load of 20mA to be within regulation band. - Specifications are for nominal input voltage, 25°C unless otherwise stated.
- When used in Cover Kit, de-rate output power to 70 % under all operating conditions
- Class II version available, Add "-II" suffix at the end of the Model Number.
- Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
- 225W with 13CFM forced air cooilng and 120W with natural convection cooling at 100 to 264VAC.
- Output ripple can be more than 10 % of the output voltage.
- Adjustment potentiometer is located on the SMT side of the PCB.
- The extended warranty period is 7 years from the date of manufacture and will continue for 6 months thereafter to allow for transport and stock holding prior to end customer receipt.
The extended warranty is a “return to base” warranty and does not imply a guarantee of 7 year operation. The standard EOS warranty T & C ’s apply for the extended warranty period.
Refer to your local EOS representative for further details.
Derating Curve
![]() |
Convection load: 120W up to 40 °C De-rate between 40-50 °C @ 0.625 % per °C De-rate above 50 °C @ 2.33 % per °C Forced air cooled load : 225W up to 50°C De-rate above 50 °C @ 2.5 % per °C |
EMC
Parameter | Conditions/Description | Criteria |
Conducted Emissions | EN 55011-B,CISPR22-B, FCC PART15-B | Pass |
Radiated Emissions | EN 55011 A |
Pass Level B with external core (King core K5B RC 25x12x15-M in input cable) |
Input Current Harmonics | EN 61000-3-2 | Class D |
Voltage Fluctuation and Flicker | EN 61000-3-3 | Pass |
ESD Immunity | EN 61000-4-2 | Level 4, Criterion A |
Radiated Field Immunity | EN 61000-4-3 | Level 3, Criterion A |
Electrical Fast Transient Immunity | EN 61000-4-4 | Level 3, Criterion A |
Surge Immunity | EN 61000-4-5 | Level 3, Criterion A |
Conducted Immunity | EN 61000-4-6 | Level 3, Criterion A |
Magnetic Field Immunity | EN 61000-4-8 | Level 4, Criterion A |
Voltage dips, interruptions | EN 61000-4-11 | Criterion B |
Safety
CE Mark | Complies with LVD Directive |
Safety Standard(s) | EN60601-1, IEC 60601-1 (ed.3), ANSI / AAMI ES 60601 - 1, CSA C22.2 No. 60601-1 |
Approval Agency | Nemko, UL, C-UL |
Safety File Number(s) |
Class I UL: Certificate Number 20141230-E173812, Nemko: Certificate No: P14219157, CB Test Certificate No :NO83948 Class II UL: Certificate Number 20141230-E173812, Nemko: Certificate No: P14219181, CB Test Certificate No: NO84076 |
Mechanical Specifications
AC Input Connector (J1) | Molex: 26-60-4030 Mating: 09-50-3031; Pins: 08-50-0106 |
Pin 1 Pin 2 Pin 3 |
AC LINE NOT FITTED AC NEUTRAL |
DC Ouput Connector (J2) Option 1 (Screw Terminal) |
Molex: 39357 Series or equivalent |
Pin 1,2,3 Pin 4,5,6 |
V1 +VE V1 -VE |
DC Ouput Connector (J2) Option 2 (Molex Connector) |
Molex: 26-60-4060 Mating: 09-50-3061; Pins: 08-50-0106 |
Pin 1,2,3 Pin 4,5,6 |
V1 +VE V1 -VE |
Aux (Fan) Output(J3) | AMP :640456-2 Mating: 640440-2 |
Pin 1 Pin 2 |
FAN +VE FAN -VE |
Screw Terminal
WLP225-1.jpg)
Tyco Header
WLP225-2.png)
-
General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.