Inquiry

FLS250

SILENT SERIES
FLS250

The New FLS250 series is true fanless power up to 250W. this is a highly efficient power supply that can deliver up to 350W with air. The power supply is packed in 4.5" x 2.5" size having the option of industry-standard 2" x 4" or 3" x 5" like a mounting option. Also available in various type of casing option.

FEATURES
  • 4.5 x 2.5 x 1.5
  • Mounting as per 4 x 2 footprint/ 3 x 5 footprint
  • 250 Watts Convection Cooled & 350 Watts Forced Cooled
  • Efficiency up to 94%
  • -40 to 70 °C operating temperature
  • High power density : 20.74W/inch3
  • IEC/EN/UL 62368 Ed 3.0 compliant
  • Current Sharing (Optional with ADD-ON CARD)
  • 12 V Fan O/P / Thermal Shut-Down feature / Dual fusing
  • 5 V STBY/ PGPF Signal / Remote ON-OFF Feature (Optional)
  • 800K Hours, Telcordia -SR332-issue 3 MTBF
  • No Load Power < 1W
  • Available with metal enclosures/accessories
AVAILABLE WITH COVER KIT
FLS250_Coverkit

FLS250-CK Series


Input Specifications
Input Voltage                 85-264 VAC/370 VDC, Universal (Derate from 100% at 100V AC to 80% & above 264VAC De-rate to 80%)
Input Frequency 47-63 Hz
Input Current 6.3 A max
No Load Power less than 1 W typical
Inrush Current 115 VAC – 25 A, 230 VAC – 45 A, 264 VAC – 75 A
Power Factor Exceeds 0.95 at Full Load
Output Specifications
Output Voltage From 12V to 58V (Refers model number matrix table)                                                            
Output Power 250W Convection & 350W with 375LFM
Output Voltage Adjustment +/-3 %
Hold-up Time 8mS Typical (At 230VAC)
Line Regulation +/-0.5 %
Load Regulation +/-0.5 %
Minimum Load 0.0 A
Transient Response max excursion 5%; 50% step load change at 0.1A/uS slew rate, 50% duty cycle, 50Hz, recovery time < 5 ms
Rise Time 55 ms typical
Set Point Tolerance +/-1 %
Over Current Protection > 110 %, Hiccup mode / Auto Recovery
Over Voltage Protection 110 to 140 %, Hiccup mode / Auto Recovery
Short Circuit Protection Hiccup mode / Auto Recovery
Cooling 350W with 375 LFM forced air cooling at 100 to 264VAC
250W with natural convection cooling at 100 to 264VAC
General Specifications
Efficiency 94%(48V, 58V), 93%(24V,30V), 92%(12V,15V)                                               
Isolation Voltage Input to Output – 4000 VDC
Input to GND - 2500 VDC
MTBF 800K Hours, Telcordia -SR332-issue 3
Leakage Current 300 uA Typical
Dimensions 4.5 x 2.5 x 1.58 inches
(114.30 x 63.5 x 40 mm)
Weight 400 gm approx
Environmental Specifications
Operating Temperature - 40 to +70°C, (-40 to 0°C startup is guaranteed with spec deviation)2                                           
Storage Temperature -40 to +85°C
Relative Humidity 5 % to 95 %, noncondensing
Altitude Operating: 16,000 ft.; Non-operating: 40,000 ft
Switching Frequency PFC – 70 to 130 KHz ,PWM – 50-80 KHz
Model Number Description Voltage Max. Load
(Convection)
Max. Load (Convection)
(375 LFM)
Min. Load Ripple1
FLS250-1012With Screw Terminal12 V16.60 A25.00 A0.00 A2 %
FLS250-1312with JST Connector12 V16.60 A18.00 A0.00 A2 %
FLS250-1015With Screw Terminal15 V13.30 A20.00 A0.00 A2 %
FLS250-1315with JST Connector15 V13.30 A18.00 A0.00 A2 %
FLS250-1024With Screw Terminal24 V10.41 A14.50 A0.00 A1 %
FLS250-1324with JST Connector24 V10.41 A14.50 A0.00 A1 %
FLS250-1030With Screw Terminal30 V8.30 A11.60 A0.00 A1 %
FLS250-1330with JST Connector30 V8.30 A11.60 A0.00 A1 %
FLS250-1048With Screw Terminal48 V5.20 A7.20 A0.00 A1 %
FLS250-1348with JST Connector48 V5.20 A7.20 A0.00 A1 %
FLS250-1058With Screw Terminal58 V4.30 A6.0 A0.00 A1 %
FLS250-1358with JST Connector58 V4.30 A6.0 A0.00 A1 %
Add Suffix “H” for I/P voltage operation up to 305VAC,example: FLS250-1024-H
Add Suffix “B“ for 3 X 5 Mounting option, example FLS250-1024-B
For Power supply unit with L bracket (metal accessory option) add "-L" suffix at the end of model number
For Power supply unit with U channel (metal accessory option) add "-U" suffix at the end of model number
For Power supply unit with CK Cover kit (metal accessory option) add "-CK" suffix at the end of model number
For Current Sharing (ADD-ON CARD) Option contact sales person
For 5V STBY / Remote ON-OFF / PGPF used model number FLS250-2XXX (Contact Sales for more details)
FLS250-CK Metal Cover Kit Accessory Available.
General Notes:
  • ”***” mark content available only in FLS250-2XXX series
  • ”***” Standby output voltage 5 V/ 0.5A(convection) with tolerance including set point accuracy, line and load regulation is +/-10 %.Ripple and noise is less than 5 %.
  • Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-10 % and Ripple and noise is less than 10 %
  • Specifications are for nominal input voltage, 25°C unless otherwise stated
  • When used in Cover Kit, de-rate output power to 70% under all operating conditions
Notes:
  1. Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
  2. Output ripple can be more than 1 % of the output voltage.
  3. 250W with natural convection cooling at 100 to 264VAC.
  4. 350W with Forced cooling at 100 to 264VAC.
  5. Combine Output Power of Main Output, Fan supply and Standby shall not exceed max power rating
Signals
Power Good : Is a TTL signal which goes high after main output reaches 90% of its set value.
The delay is 0.1 s to 0.5 s
Power Fail : The same signal goes low at least 1ms before main output falls to 90% of set value at AC Power off








Power Good /Power Fail Signal
MULP180
Remote on/off : Shorting Pin 3 to Pin 4 enables main output while keeping the Pins open disables main output.








Remote On/Off Signal
FLS250 Series
Voltage Sense Signal Drawing




Voltage Sense
FLS250 Series voltage sense
Derating Curve
FLS250 o/p derating and i/p derating De-rate linearly from 100% at 100VAC to 80% at 85VAC
FLS250 derating curve 24 to 58v Convection load: 250W up to 40 °C
De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C


Forced air cooled load: 350W up to 40 °C
De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C
fls250 derating curve of 12 to 15v cover kit Convection load: 200W up to 40 °C
De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C


Forced air cooled load: 300W up to 40 °C
De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C
FLS250 derating for CK Bracket Convection load: 175W up to 40 °C
De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C
FLS250 derating for H models De-rate linearly from 100% at 100VAC to 80% at 85VAC & above 264VAC De-rate to 80%
EMC
Parameter Conditions/Description Criteria
Conducted Emissions EN 55032-B, CISPR22-B, FCC PART15-B Pass
Radiated Emissions EN 55032 A Pass
Level B with external core (King core K5B RC 25x12x15-M or Equivalent in input cable)
Input Current Harmonics EN 61000-3-2 Class A
Voltage Fluctuation and Flicker EN 61000-3-3
ESD Immunity EN 61000-4-2 Level 3, Criterion A
Radiated Field Immunity EN 61000-4-3 Level 3, Criterion A
Electrical Fast Transient Immunity EN 61000-4-4 Level 3, Criterion A
Surge Immunity EN 61000-4-5 Level 3, Criterion A
Conducted Immunity EN 61000-4-6 Level 3, Criterion A
Magnetic Field Immunity EN 61000-4-8 Level 3, Criterion A
Voltage dips, interruptions EN 61000-4-11 Criterion A & B
Safety
CE Mark Complies with LVD Directive
Safety Standard(s) IEC62368-1:2018,
EN62368-1:2020;A11
UL 62368-1 ED 3.0 and CAN/CSA C22.2 No. 62368-1:19
Approval Agency Nemko, UL, C-UL
Safety File Number(s) Class-I : UL : Certificate No: E515384, Nemko: Certificate No.: P21225619, CB Ref. Certificate No.: NO118753
Downloads
CB Class - I Certificate
Nemko Class - I Certificate
UL Class - I Certificate
Mechanical Specifications
AC Input Connector (J1) Molex: 26-60-4030
Mating: 09-50-3031; Pins: 08-50-0106
Pin 1
Pin 2
Pin 3
AC LINE
NOT FITTED
AC NEUTRAL
DC Ouput Connector (J2) Option 1
(Screw Terminal)
Molex: 39357 Series or equivalent Pin 1,2,3
PIN 4,5,6
V1 +VE
V1 -VE
DC Ouput Connector (J2) Option 2
(JST Connector)
JST p/n: B6P-VH(LF)(SN)
Mating: JST p/n: VHR-6M; Pins: SVH-41T-P1.1
Pin 1,2,3
PIN 4,5,6
V1 +VE
V1 -VE
Signal Connector (J9) Molex Part No: 10-89-7041 or equivalent
Mating part no: 1053082204 ; Pins: 1053001100
Pin 1
Pin 2
Pin 3
Pin 4
+VS
-VS
FAN -
FAN +
J(310)
(Multifunction Connector)***
HEADER 5POS 2.54MM) P/N : P9102-40-12-1
Mating part no : CONN RCPT HSNG 5POS CST-100 II P/N :1375820-5
Pins : CONN SOCKET 22-26AWG CRIMP TIN P/N : 1375819-1
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
+5V
GND
GND
REMOTE ON/OFF
PGPF
EARTH (J4) Molex: 19705-4301
Mating: 19003-0001
Screw terminal (1XXX/ 2XXX)
FLS250-Screw terminal-1
Header terminal (1XXX/ 2XXX)
FLS250-Header terminal-1
Screw terminal (1XXX-B/ 2XXX-B)
FLS250-Screw terminal-2
Header terminal (1XXX-B/ 2XXX-B)
FLS250-Header terminal-2
    General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following
  1. Stand off, used to mount PCB has OD of 5.4 mm max.
  2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
  3. Washer, if used, to have dia of 6.5 mm max.
Mechnical Drawing

FLS250 2.5 X 4.5 with L-Bracket

FLS250-2x5 series with L Bracket
Mechnical Drawing

FLS250 3 X 5 with L -Bracket

FLS250-3x5 series with L Bracket
Mechnical Drawing

FLS250 2.5 X 4.5 with U Channel

FLS250-2.5 X 4.5 series with U Channel
Mechnical Drawing

FLS250 3 X 5 with U Channel

FLS250-3 X 5 series with U Channel
Mechnical Drawing

FLS250 2.5 X 4.5 with Cover kit

FLS250 2.5 X 4.5 with Cover kit
Mechnical Drawing

FLS250 3 X 5 with Cover kit

FLS250 3 X 5 with Cover kit
Mechnical Drawing

FLS250 2.5 X 4.5 with Cover kit - Fan

FLS250 2.5 X 4.5 with Cover kit - Fan
Mechnical Drawing

FLS250 3 X 5 with Cover kit - Fan

FLS250 3 X 5 with Cover kit-fan
Approvals
Certificate Standard Downloads
CB Class - I Certificate IEC 62368-1:2018
Nemko Class - I Certificate EN 62368-1:2020;A11
UL Class - I Certificate UL 62368-1 and CAN/CSA C22.2 No. 62368-1