FLS250
The New FLS250 series is true fanless power up to 250W. this is a highly efficient power supply that can deliver up to 350W with air. The power supply is packed in 4.5" x 2.5" size having the option of industry-standard 2" x 4" or 3" x 5" like a mounting option. Also available in various type of casing option.
FEATURES
- 4.5 x 2.5 x 1.5
- Mounting as per 4 x 2 footprint/ 3 x 5 footprint
- 250 Watts Convection Cooled & 350 Watts Forced Cooled
- Efficiency up to 94%
- -40 to 70 °C operating temperature
- High power density : 20.74W/inch3
- IEC/EN/UL 62368 Ed 3.0 compliant
- Current Sharing (Optional with ADD-ON CARD)
- 12 V Fan O/P / Thermal Shut-Down feature / Dual fusing
- 5 V STBY/ PGPF Signal / Remote ON-OFF Feature (Optional)
- 800K Hours, Telcordia -SR332-issue 3 MTBF
- No Load Power < 1W
- Available with metal enclosures/accessories
- Electrical Specifications
- Signals
- Derating Curve
- EMC & Safety
- Mechanical Specifications
- Certificates
- Order Information
Input Specifications
Input Voltage                 | 85-264 VAC/370 VDC, Universal (Derate from 100% at 100V AC to 80% & above 264VAC De-rate to 80%) | |
Input Frequency | 47-63 Hz | |
Input Current | 6.3 A max | |
No Load Power | less than 1 W typical | |
Inrush Current | 115 VAC – 25 A, 230 VAC – 45 A, 264 VAC – 75 A | |
Power Factor | Exceeds 0.95 at Full Load |
Output Specifications
Output Voltage | From 12V to 58V (Refers model number matrix table)                                                             | |
Output Power | 250W Convection & 350W with 375LFM | |
Output Voltage Adjustment | +/-3 % | |
Hold-up Time | 8mS Typical (At 230VAC) | |
Line Regulation | +/-0.5 % | |
Load Regulation | +/-0.5 % | |
Minimum Load | 0.0 A | |
Transient Response | max excursion 5%; 50% step load change at 0.1A/uS slew rate, 50% duty cycle, 50Hz, recovery time < 5 ms | |
Rise Time | 55 ms typical | |
Set Point Tolerance | +/-1 % | |
Over Current Protection | > 110 %, Hiccup mode / Auto Recovery | |
Over Voltage Protection | 110 to 140 %, Hiccup mode / Auto Recovery | |
Short Circuit Protection | Hiccup mode / Auto Recovery | |
Cooling | 350W with 375 LFM forced air cooling at 100 to 264VAC 250W with natural convection cooling at 100 to 264VAC |
General Specifications
Efficiency | 94%(48V, 58V), 93%(24V,30V), 92%(12V,15V)                                                | |
Isolation Voltage | Input to Output – 4000 VDC Input to GND - 2500 VDC |
|
MTBF | 800K Hours, Telcordia -SR332-issue 3 | |
Leakage Current | 300 uA Typical | |
Dimensions | 4.5 x 2.5 x 1.58 inches (114.30 x 63.5 x 40 mm) |
|
Weight | 400 gm approx |
Environmental Specifications
Operating Temperature | - 40 to +70°C, (-40 to 0°C startup is guaranteed with spec deviation)2                                            | |
Storage Temperature | -40 to +85°C | |
Relative Humidity | 5 % to 95 %, noncondensing | |
Altitude | Operating: 16,000 ft.; Non-operating: 40,000 ft | |
Switching Frequency | PFC – 70 to 130 KHz ,PWM – 50-80 KHz |
Model Number | Description | Voltage | Max. Load
(Convection) |
Max. Load (Convection) (375 LFM) |
Min. Load | Ripple1 | |
FLS250-1012 | With Screw Terminal | 12 V | 16.60 A | 25.00 A | 0.00 A | 2 % | |
FLS250-1312 | with JST Connector | 12 V | 16.60 A | 18.00 A | 0.00 A | 2 % | |
FLS250-1015 | With Screw Terminal | 15 V | 13.30 A | 20.00 A | 0.00 A | 2 % | |
FLS250-1315 | with JST Connector | 15 V | 13.30 A | 18.00 A | 0.00 A | 2 % | |
FLS250-1024 | With Screw Terminal | 24 V | 10.41 A | 14.50 A | 0.00 A | 1 % | |
FLS250-1324 | with JST Connector | 24 V | 10.41 A | 14.50 A | 0.00 A | 1 % | |
FLS250-1030 | With Screw Terminal | 30 V | 8.30 A | 11.60 A | 0.00 A | 1 % | |
FLS250-1330 | with JST Connector | 30 V | 8.30 A | 11.60 A | 0.00 A | 1 % | |
FLS250-1048 | With Screw Terminal | 48 V | 5.20 A | 7.20 A | 0.00 A | 1 % | |
FLS250-1348 | with JST Connector | 48 V | 5.20 A | 7.20 A | 0.00 A | 1 % | |
FLS250-1058 | With Screw Terminal | 58 V | 4.30 A | 6.0 A | 0.00 A | 1 % | |
FLS250-1358 | with JST Connector | 58 V | 4.30 A | 6.0 A | 0.00 A | 1 % | |
Add Suffix “H” for I/P voltage operation up to 305VAC,example: FLS250-1024-H Add Suffix “B“ for 3 X 5 Mounting option, example FLS250-1024-B For Power supply unit with L bracket (metal accessory option) add "-L" suffix at the end of model number For Power supply unit with U channel (metal accessory option) add "-U" suffix at the end of model number For Power supply unit with CK Cover kit (metal accessory option) add "-CK" suffix at the end of model number For Current Sharing (ADD-ON CARD) Option contact sales person For 5V STBY / Remote ON-OFF / PGPF used model number FLS250-2XXX (Contact Sales for more details) |
|||||||
FLS250-CK Metal Cover Kit Accessory Available. |
General Notes:
- ”***” mark content available only in FLS250-2XXX series
- ”***” Standby output voltage 5 V/ 0.5A(convection) with tolerance including set point accuracy, line and load regulation is +/-10 %.Ripple and noise is less than 5 %.
- Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-10 % and Ripple and noise is less than 10 %
- Specifications are for nominal input voltage, 25°C unless otherwise stated
- When used in Cover Kit, de-rate output power to 70% under all operating conditions
- Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
- Output ripple can be more than 1 % of the output voltage.
- 250W with natural convection cooling at 100 to 264VAC.
- 350W with Forced cooling at 100 to 264VAC.
- Combine Output Power of Main Output, Fan supply and Standby shall not exceed max power rating
Signals
Power Good : Is a TTL signal which goes high after main output reaches 90% of its set value. The delay is 0.1 s to 0.5 s Power Fail : The same signal goes low at least 1ms before main output falls to 90% of set value at AC Power off |
|
Power Good /Power Fail Signal |
|
Remote on/off : Shorting Pin 3 to Pin 4 enables main output while keeping the Pins open disables main output. | |
Remote On/Off Signal |
|
Voltage Sense Signal Drawing | |
Voltage Sense |
Derating Curve
De-rate linearly from 100% at 100VAC to 80% at 85VAC | |
Convection load: 250W up to 40 °C De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C Forced air cooled load: 350W up to 40 °C De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C |
|
Convection load: 200W up to 40 °C De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C Forced air cooled load: 300W up to 40 °C De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C |
|
Convection load: 175W up to 40 °C De-rate Between 40°C -50°C @ 1.2 % per °C above 50 °C @ 1.67 % per °C |
|
De-rate linearly from 100% at 100VAC to 80% at 85VAC & above 264VAC De-rate to 80% |
EMC
Parameter | Conditions/Description | Criteria |
Conducted Emissions | EN 55032-B, CISPR22-B, FCC PART15-B | Pass |
Radiated Emissions | EN 55032 A |
Pass Level B with external core (King core K5B RC 25x12x15-M or Equivalent in input cable) |
Input Current Harmonics | EN 61000-3-2 | Class A |
Voltage Fluctuation and Flicker | EN 61000-3-3 | |
ESD Immunity | EN 61000-4-2 | Level 3, Criterion A |
Radiated Field Immunity | EN 61000-4-3 | Level 3, Criterion A |
Electrical Fast Transient Immunity | EN 61000-4-4 | Level 3, Criterion A |
Surge Immunity | EN 61000-4-5 | Level 3, Criterion A |
Conducted Immunity | EN 61000-4-6 | Level 3, Criterion A |
Magnetic Field Immunity | EN 61000-4-8 | Level 3, Criterion A |
Voltage dips, interruptions | EN 61000-4-11 | Criterion A & B |
Safety
CE Mark | Complies with LVD Directive |
Safety Standard(s) |
IEC62368-1:2018, EN62368-1:2020;A11 UL 62368-1 ED 3.0 and CAN/CSA C22.2 No. 62368-1:19 |
Approval Agency | Nemko, UL, C-UL |
Safety File Number(s) | Class-I : UL : Certificate No: E515384, Nemko: Certificate No.: P21225619, CB Ref. Certificate No.: NO118753 |
Mechanical Specifications
AC Input Connector (J1) | Molex: 26-60-4030 Mating: 09-50-3031; Pins: 08-50-0106 |
Pin 1 Pin 2 Pin 3 |
AC LINE NOT FITTED AC NEUTRAL |
DC Ouput Connector (J2) Option 1 (Screw Terminal) |
Molex: 39357 Series or equivalent |
Pin 1,2,3 PIN 4,5,6 |
V1 +VE V1 -VE |
DC Ouput Connector (J2) Option 2 (JST Connector) |
JST p/n: B6P-VH(LF)(SN) Mating: JST p/n: VHR-6M; Pins: SVH-41T-P1.1 |
Pin 1,2,3 PIN 4,5,6 |
V1 +VE V1 -VE |
Signal Connector (J9) | Molex Part No: 10-89-7041 or equivalent Mating part no: 1053082204 ; Pins: 1053001100 |
Pin 1 Pin 2 Pin 3 Pin 4 |
+VS -VS FAN - FAN + |
J(310) (Multifunction Connector)*** |
HEADER 5POS 2.54MM) P/N : P9102-40-12-1 Mating part no : CONN RCPT HSNG 5POS CST-100 II P/N :1375820-5 Pins : CONN SOCKET 22-26AWG CRIMP TIN P/N : 1375819-1 |
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 |
+5V GND GND REMOTE ON/OFF PGPF |
EARTH (J4) | Molex: 19705-4301 Mating: 19003-0001 |
Screw terminal (1XXX/ 2XXX)
Header terminal (1XXX/ 2XXX)
Screw terminal (1XXX-B/ 2XXX-B)
Header terminal (1XXX-B/ 2XXX-B)
-
General Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following
- Stand off, used to mount PCB has OD of 5.4 mm max.
- Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
- Washer, if used, to have dia of 6.5 mm max.
Mechnical Drawing
FLS250 2.5 X 4.5 with L-Bracket
Mechnical Drawing
FLS250 3 X 5 with L -Bracket
Mechnical Drawing
FLS250 2.5 X 4.5 with U Channel
Mechnical Drawing
FLS250 3 X 5 with U Channel
Mechnical Drawing
FLS250 2.5 X 4.5 with Cover kit
Mechnical Drawing
FLS250 3 X 5 with Cover kit
Mechnical Drawing
FLS250 2.5 X 4.5 with Cover kit - Fan
Mechnical Drawing
FLS250 3 X 5 with Cover kit - Fan
Nomenclature: